Biocomp - Genotox - Mouse Lymphoma Assay (MLA, Limit test)

Beyond point mutations detected by Ames testing lies another universe of genetic damage - chromosome-level changes including deletions, translocations, and recombinations that cause cancer yet bacterial tests cannot detect, demanding mammalian cell assays that capture the full spectrum of genotoxic mechanisms. The Mouse Lymphoma Assay represents the most comprehensive in vitro genotoxicity test, simultaneously detecting both gene mutations and chromosomal damage in mammalian cells following ISO 10993-3 Method C (FDA) and OECD TG490, providing critical safety data for medical devices where genetic damage poses long-term cancer risks. This sophisticated assay exposes L5178Y mouse lymphoma cells to device extracts prepared in both polar and non-polar solvents, measuring forward mutation frequency at the thymidine kinase locus while colony sizing distinguishes between point mutations producing large colonies and chromosomal damage generating small colonies indicating clastogenic effects. Regulatory authorities increasingly require Mouse Lymphoma testing for long-term implantable devices exceeding 30 days contact, devices with positive or equivocal Ames results requiring mammalian cell confirmation, and novel materials where comprehensive genotoxicity assessment proves essential for risk characterization. The limit study design tests maximum feasible concentrations ensuring that negative results genuinely indicate safety rather than insufficient exposure, with GLP compliance providing pharmaceutical-grade data quality that regulatory submissions demand for pivotal safety studies supporting premarket approvals. Critical for implantable devices where chronic material exposure creates cumulative cancer risk requiring demonstration that materials don't cause genetic damage through extended contact, cardiovascular devices where genotoxicity could initiate malignancies in critical tissues, and orthopedic implants with decades-long patient exposure demanding comprehensive genetic safety assessment. The dual assessment of mutagenicity and clastogenicity provides complete genotoxicity profiling in single assay, revealing whether materials cause point mutations affecting individual genes or chromosomal damage impacting multiple genes simultaneously, both mechanisms contributing to cancer development through different pathways.

No.
1006219
Method
Mammalian cell forward mutation assay with colony sizing
Stage category
Analyses category
Sample type
Finished device, Bulk material
Sample requirement (type)
Sterile or non sterile
Sample quantities
4 product, 300 cm2, 12,5 gram
Lead Time Standard (Days)
105
Lead Time Express (Days)
unavailable
Lead Time Super Express (Days)
52
Test facility
Partner Lab
GLP
No
Add this test to cart to request an offer.

Do you need some help?

Other similar tests

ISO 10993-1, ISO 10993-5, ISO 10993-12
Biocomp - Cytotoxicity - direct contact

Regulatory pathways for every medical device begin with cytotoxicity testing - this mandatory first screening determines whether materials cause cellular death or damage, serving as the gatekeeper preventing toxic materials from advancing to expensive animal studies or clinical trials. Direct contact cytotoxicity testing following ISO 10993-5 and ISO 10993-12 serves as the mandatory first screening in biological evaluation, required by FDA, EU MDR, and global regulatory bodies before any in vivo testing can proceed. This qualitative assessment places test materials directly onto L929 mouse fibroblast monolayers, evaluating cellular response through morphological changes including lysis, vacuolization, and detachment after 24-hour exposure at 37°C. The direct interface between material and cells provides the most stringent evaluation, detecting both leachable substances migrating from materials and surface-mediated toxicity from direct contact that extraction methods might miss. Every medical device contacting human tissue requires cytotoxicity data - from wound dressings and surgical implants to diagnostic equipment and dental materials - making this the universal starting point for biocompatibility assessment. The test proves particularly critical during material selection when comparing candidates where cytotoxicity failures eliminate options early, after manufacturing changes that could introduce contamination requiring revalidation, and for final product validation before clinical trials demonstrating material safety. The L929 mouse fibroblast cell line provides standardized, reproducible response enabling comparison across laboratories and historical data, while the 24-hour exposure duration balances sensitivity with practicality. Passing results enable progression to additional ISO 10993 testing, while failures trigger investigation of material composition, processing residues, or sterilization effects before expensive in vivo studies commence.

ISO 10993-1, ISO 10993-5, ISO 10993-12
Biocomp - Cytotoxicity - indirect contact

Some devices cannot physically contact cell monolayers - complex geometries, absorbable materials that dissolve, or devices requiring hydration before testing demand alternative approaches that still predict clinical toxicity. Agar diffusion cytotoxicity testing per ISO 10993-5 and ISO 10993-12 evaluates material biocompatibility through an intermediate barrier, simulating clinical scenarios where substances must migrate through tissue or membranes to cause adverse effects. The agar overlay technique places materials on solidified agar above L929 mouse fibroblast monolayers, with toxic substances diffusing through the agar to create zones of cellular decoloration or lysis measured after 24-hour incubation at 37°C. This method proves invaluable for materials that cannot be tested by direct contact - absorbable materials that dissolve in culture medium, devices with complex geometries preventing uniform cell contact, or materials requiring hydration before testing where direct contact proves impractical. Medical device categories requiring agar diffusion testing include wound dressings with antimicrobial agents where controlled diffusion simulates clinical release, drug-eluting implants where gradual substance migration represents intended function, and barrier membranes designed to prevent adhesion while allowing nutrient transfer. The zone of lysis measurement provides semi-quantitative assessment - larger zones indicate more severe toxicity or greater substance migration, while zone absence suggests acceptable biocompatibility. For combination products releasing therapeutic agents, agar diffusion distinguishes between acceptable controlled release and excessive elution causing cytotoxicity, supporting dose optimization. The method also accommodates testing materials in hydrated states representing clinical use, unlike direct contact requiring dry materials that may not reflect actual patient exposure.

ISO 10993-1, ISO 10993-5, ISO 10993-12
Biocomp - Cytotoxicity - extract (XTT)

Qualitative cytotoxicity observations provide pass/fail results but regulatory risk assessment demands quantitative data - calculating safety margins, comparing material alternatives, and optimizing formulations require numerical measurements that subjective morphology assessment cannot provide. Quantitative cytotoxicity assessment using XTT methodology per ISO 10993-5 and ISO 10993-12 transforms subjective morphological evaluation into objective numerical data through colorimetric measurement of mitochondrial activity in L929 fibroblasts. The extraction approach following ISO 10993-12 guidelines ensures clinical relevance simulating patient exposure, while the XTT tetrazolium reduction assay provides dose-response curves and IC50 values essential for risk assessment per ISO 10993-17. Critical applications span all device categories but particularly benefit implantables requiring biocompatibility margins demonstrating safety factors, combination products where cytotoxicity must be balanced against therapeutic efficacy, and devices with unavoidable trace toxicity requiring risk-benefit analysis through quantitative assessment. The numerical results enable statistical process control that visual methods cannot achieve - establishing control limits defining acceptable cytotoxicity ranges, calculating process capability indices demonstrating manufacturing consistency, and detecting subtle trends indicating material degradation or supplier variation before failures occur. For material development, quantitative cytotoxicity enables optimization comparing formulations where small differences prove critical, evaluating sterilization impact on toxicity through before-after comparison, and assessing aging effects demonstrating shelf-life stability. The dose-response relationship reveals whether materials exhibit threshold toxicity requiring concentration control or linear toxicity suggesting complete elimination necessity. Manufacturing validation benefits from quantitative data tracking cytotoxicity across production lots, identifying process drift before products fail qualitative screening, and demonstrating equivalence when qualifying alternative suppliers or manufacturing sites.