Chemistry - Tenax Specific migration - Full package testing

Silicone medical devices face unique analytical challenges - standard heavy metal methods designed for aqueous or organic matrices fail with silicone's unique chemistry requiring specialized digestion achieving complete dissolution. Heavy metal analysis specifically optimized for silicone materials addresses unique analytical challenges achieving ICP-MS sensitivity through specialized digestion ensuring complete matrix breakdown. Specialized digestion methods prevent volatile element loss that conventional approaches cause with silicone matrices, achieve complete matrix dissolution releasing all metals for measurement, and enable accurate quantification of catalyst residues and toxic metals. Essential for silicone implants where trace metals influence biological responses including inflammatory reactions and tissue integration, validating catalyst removal from medical-grade silicones demonstrating platinum or tin catalysts reduced to acceptable levels, and investigating adverse reactions potentially linked to metallic contamination causing sensitization or cytotoxicity. For long-term implantable silicones, metal testing validates that manufacturing adequately removes platinum catalysts from curing reactions, corrosion of metallic components doesn't contaminate silicone causing metal accumulation, and raw material suppliers provide consistent low-metal silicones meeting specifications. The ICP-MS methodology provides multi-element analysis measuring potential contaminants in single analysis, achieves sensitivity detecting metals at toxicologically relevant levels, and accommodates various silicone types from elastomers to gels. Manufacturing validation confirms processing controls metal contamination, incoming material screening detects supplier quality variations, and product testing demonstrates compliance with metal specifications throughout production ensuring consistent patient safety.

No.
1007023
Method
Acid digestion, ICP-MS for heavy metals
Standard
Analyses category
Sample type
Finished device, Bulk material
Sample requirement (type)
Sterile or non sterile
Sample quantities
1 product
Lead Time Standard (Days)
unavailable
Lead Time Express (Days)
unavailable
Lead Time Super Express (Days)
unavailable
Test facility
Partner Lab
GLP
No
Add this test to cart to request an offer.

Do you need some help?

Other similar tests

ISO 10993-18, EU 10/2011
Chemistry - BDDE analysis

Epoxy resins and coatings contain BADGE (Bisphenol A diglycidyl ether) and derivatives that migrate into contacted substances creating endocrine disruption concerns requiring sensitive detection distinguishing BADGE from related compounds. BADGE (Bisphenol A diglycidyl ether) analysis by GC-MS targets epoxy components that migrate from coatings and adhesives with methodology preventing hydrolysis while ensuring complete detection. Careful handling prevents BADGE hydrolysis to hydroxylated derivatives during analysis, derivatization ensures complete detection of BADGE and transformation products, and chromatographic separation distinguishes BADGE from structurally similar compounds. Critical for devices with epoxy adhesives requiring validation that curing adequately reacts BADGE preventing migration, coated metal components where epoxy linings protect contents but potentially release BADGE, and demonstrating compliance with restrictions on bisphenol-related compounds increasingly targeted by regulations. For medical devices using epoxy coatings in fluid pathways, BADGE testing validates that coating formulation and cure conditions minimize residual monomers, migration under simulated use remains below regulatory limits, and aging doesn't increase BADGE release through coating degradation. The analysis accommodates various BADGE derivatives including hydrolyzed products formed during migration or storage, quantifies both BADGE monomers and higher molecular weight oligomers, and supports risk assessment calculating exposure from measured levels. Manufacturing validation confirms epoxy curing achieves adequate BADGE reaction, coating application processes don't introduce excess BADGE through incomplete mixing, and quality control detects batches with elevated BADGE requiring corrective action. The testing supports "BPA-free" claims by confirming epoxy alternatives don't introduce BADGE or similar bisphenol-derived epoxy compounds with comparable endocrine activity concerns.

ISO 10993-18, EU 10/2011
Chemistry - Bisphenol (without extraction)

Direct bisphenol analysis in liquid samples eliminates extraction complexity yet maintains sensitivity - testing extracts, process liquids, or formulations requires rapid methods avoiding elaborate sample preparation while achieving regulatory detection limits. Direct bisphenol analysis in liquid samples using GC-MS with BSTFA derivatization ensures complete detection of BPA and related compounds through chemical derivatization enhancing volatility and detectability. This rapid approach eliminates extraction steps reducing analysis time and cost while achieving sensitivity below regulatory thresholds protecting against endocrine disruption concerns. Critical for analyzing device extracts testing leachable bisphenol content from polycarbonate or epoxy materials, monitoring BPA in liquid products ensuring purity meeting regulatory requirements, and validating "BPA-free" claims for liquid-contact materials demonstrating absence below detection limits. The BSTFA derivatization converts bisphenols to trimethylsilyl derivatives improving GC separation and mass spectral detection, enabling sensitive quantification in complex matrices containing interfering substances. For medical devices contacting aqueous solutions, direct analysis of extracts reveals bisphenol leaching under simulated use conditions, supporting biocompatibility assessment and toxicological risk evaluation. Manufacturing applications include validation testing process liquids ensuring BPA-free status, quality control of incoming liquid components, and investigation of unexpected estrogenic activity potentially caused by bisphenol contamination. The method accommodates various bisphenol analogs beyond BPA including BPS and BPF enabling comprehensive screening as regulations expand beyond traditional BPA restrictions to encompass structurally related compounds with similar endocrine activity.

ISO 10993-18, EU 10/2011
Chemistry - Bisphenol (extraction included)

Solid materials containing bisphenols require extraction releasing these endocrine disruptors before analysis - polycarbonate plastics, epoxy coatings, and thermal paper all harbor bisphenols needing specialized extraction for quantification. Bisphenol analysis with extraction addresses solid materials and complex matrices using GC-MS with derivatization for comprehensive detection following sample extraction. The extraction approach ensures complete recovery of free and bound bisphenols from various materials including polycarbonate where BPA comprises the polymer backbone, epoxy resins where bisphenols serve as curing agents, and thermal papers using bisphenols as color developers. Essential for validating BPA-free claims in medical devices demonstrating polycarbonate alternatives or coatings don't contain bisphenols, investigating endocrine disruption concerns when biological testing reveals estrogenic activity, and demonstrating compliance with expanding bisphenol restrictions across global markets. The extraction methodology releases bisphenols from polymer matrices through solvent extraction or thermal desorption, quantifies both monomeric bisphenols and oligomers that migrate during use, and accommodates various sample forms from powders to fabricated devices. For medical device materials, bisphenol testing validates that BPA-free formulations genuinely lack these compounds rather than containing structural analogs with similar endocrine activity. Manufacturing validation confirms processing doesn't introduce bisphenol contamination from equipment or additives, alternative materials marketed as BPA-free don't contain related bisphenols like BPS or BPF, and sterilization doesn't cause polymer degradation releasing bisphenols. The testing supports regulatory submissions demonstrating compliance with bisphenol restrictions, responds to customer requirements increasingly specifying bisphenol-free materials, and addresses stakeholder concerns about endocrine disruption from medical device exposure.